This requirement is especially applicable to bracelet anodes where there may be a possibility of anodes being covered by insulating material or antibuoyancy material. The reinforcement of concrete weight coating should not be allowed to be in electrical contact with pipe or anode.Ĭare should be exercised so as not to reduce the design surface area in contact with the electrolyte. Each anode should be electrically connected to the pipe by at least two attachments, preferably one from each half bracelet. The two segments may be welded together with steel strips to ensure satisfactory mechanical connection and proper positioning. Anode bracelets should be fastened securely on the pipe. It is important that the anodes be mounted in a manner so as to avoid mechanical damage during handling and installation of pipes. Galvanic anode systems should be installed in accordance with design specifications and drawings. Alireza Bahadori Ph.D., in Cathodic Corrosion Protection Systems, 2014 7.10.2 Installation of Galvanic Anode Systems